MSG0016: An error occurred trying to determine the DC for this system. You will not be allowed to proceed (error 0x51f)

Solution #00007410
Scope:
ArchiveOne Enterprise, all versions

Answer:

PROBLEM
When attempting to open the ArchiveOne Admin console, you receive the error:"MSG0016: An error occurred trying to determine the DC for this system. You will not be allowed to proceed (error 0x51f)"

When viewing the trace logs you will see an error regarding GETDCNAME.

ROOT CAUSE
This is typically caused by issues with Domain Controllers communicating or replicating.

RESOLUTION
It is recommended that you run the Windows tool DCDIAG to try to determine what the issue with the DC is and then take steps to correct the problem.